Thông tin chi tiết của sản phẩm
Cầu đấu điện vặn vít Phoenix Contact UT 4 - 3044102
(Feed-through terminal block 1000V 32A 1 tầng 0.14-6mm²)
Feed-through terminal block, nom. voltage: 1000 V, nominal current: 32 A, connection method: Screw connection, number of connections: 2, cross section: 0.14 mm² - 6 mm², AWG: 26 - 10, width: 6.2 mm, height: 46.9 mm, color: gray, mounting type: NS 35/7,5, NS 35/15
Ưu điểm
- The large wiring space enables the connection of solid and stranded conductors without ferrules, even above the nominal cross section
- As well as saving space, the compact design enables user-friendly wiring in a small amount of space
- Optimum screwdriver guidance through closed screw shafts
- The cable entry funnel enables the use of conductors with ferrules and plastic collars within the nominal cross section
- Tested for railway applications
Thông số kỹ thuật chung
| Number of levels |
1 |
| Number of connections |
2 |
| Potentials |
1 |
| Nominal cross section |
4 mm² |
| Color |
gray |
| Insulating material |
PA |
| Flammability rating according to UL 94 |
V0 |
| Area of application |
Railway industry |
| |
Machine building |
| |
Plant engineering |
| |
Process industry |
| Rated surge voltage |
8 kV |
| Degree of pollution |
3 |
| Overvoltage category |
III |
| Insulating material group |
I |
| Maximum power dissipation for nominal condition |
1.02 W |
| Maximum load current |
41 A (with 6 mm² conductor cross section) |
| Nominal current IN |
32 A (with 4 mm² conductor cross section) |
| Nominal voltage UN |
1000 V |
| Open side panel |
Yes |
| Ambient temperature (operation) |
-60 °C ... 105 °C (max. short-term operating temperature 130°C) |
| Ambient temperature (storage/transport) |
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Permissible humidity (storage/transport) |
30 % ... 70 % |
| Ambient temperature (assembly) |
-5 °C ... 70 °C |
| Ambient temperature (actuation) |
-5 °C ... 70 °C |
| Shock protection test specification |
DIN EN 50274 (VDE 0660-514):2002-11 |
| Back of the hand protection |
guaranteed |
| Finger protection |
guaranteed |
| Result of surge voltage test |
Test passed |
| Result of power-frequency withstand voltage test |
Test passed |
| Power frequency withstand voltage setpoint |
2.2 kV |
| Result of the test for mechanical stability of terminal points (5 x conductor connection) |
Test passed |
| Result of bending test |
Test passed |
| Bending test rotation speed |
10 rpm |
| Bending test turns |
135 |
| Bending test conductor cross section/weight |
0.14 mm² / 0.2 kg |
| |
4 mm² / 0.9 kg |
| |
6 mm² / 1.4 kg |
| Tensile test result |
Test passed |
| Result of tight fit on support |
Test passed |
| Tight fit on carrier |
NS 35 |
| Setpoint |
1 N |
| Result of voltage-drop test |
Test passed |
| Result of temperature-rise test |
Test passed |
| Requirement temperature-rise test |
Increase in temperature ≤ 45 K |
| Short circuit stability result |
Test passed |
| Conductor cross section short circuit testing |
4 mm² |
| Short-time current |
0.48 kA |
| Conductor cross section short circuit testing |
6 mm² |
| Short-time current |
0.72 kA |
| Result of thermal test |
Test passed |
| Proof of thermal characteristics (needle flame) effective duration |
30 s |
| Oscillation, broadband noise test result |
Test passed |
| Test specification, oscillation, broadband noise |
DIN EN 50155 (VDE 0115-200):2008-03 |
| Test spectrum |
Service life test category 1, class B, body mounted |
| Test frequency |
f1 = 5 Hz to f2 = 150 Hz |
| ASD level |
1.857 (m/s2)2/Hz |
| Acceleration |
0,8 g |
| Test duration per axis |
5 h |
| Test directions |
X-, Y- and Z-axis |
| Shock test result |
Test passed |
| Test specification, shock test |
DIN EN 50155 (VDE 0115-200):2008-03 |
| Shock form |
Half-sine |
| Acceleration |
5g |
| Shock duration |
30 ms |
| Number of shocks per direction |
3 |
| Test directions |
X-, Y- and Z-axis (pos. and neg.) |
| Relative insulation material temperature index (Elec., UL 746 B) |
130 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) |
125 °C |
| Static insulating material application in cold |
-60 °C |
| Surface flammability NFPA 130 (ASTM E 162) |
passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) |
passed |
| Calorimetric heat release NFPA 130 (ASTM E 1354) |
27,5 MJ/kg |
| Smoke gas toxicity NFPA 130 (SMP 800C) |
passed |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 |
HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 |
HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 |
HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 |
HL 1 - HL 3 |
Kích thước
| Width |
6.2 mm |
| End cover width |
2.2 mm |
| Length |
47.7 mm |
| Height |
46.9 mm |
| Height NS 35/7,5 |
47.5 mm |
| Height NS 35/15 |
55 mm |
Thông số đấu nối
| Connection method |
Screw connection |
| Screw thread |
M3 |
| Stripping length |
9 mm |
| Tightening torque, min |
0.6 Nm |
| Tightening torque max |
0.8 Nm |
| Connection in acc. with standard |
IEC 60947-7-1 |
| Note |
Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area. |
| Conductor cross section solid min. |
0.14 mm² |
| Conductor cross section solid max. |
6 mm² |
| Conductor cross section AWG min. |
26 |
| Conductor cross section AWG max. |
10 |
| Conductor cross section flexible min. |
0.14 mm² |
| Conductor cross section flexible max. |
6 mm² |
| Min. AWG conductor cross section, flexible |
26 |
| Max. AWG conductor cross section, flexible |
10 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. |
0.14 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. |
4 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. |
0.14 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. |
4 mm² |
| 2 conductors with same cross section, solid min. |
0.14 mm² |
| 2 conductors with same cross section, solid max. |
1.5 mm² |
| 2 conductors with same cross section, stranded min. |
0.14 mm² |
| 2 conductors with same cross section, stranded max. |
1.5 mm² |
| Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum |
0.5 mm² |
| Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum |
2.5 mm² |
| Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum |
0.14 mm² |
| Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum |
1.5 mm² |
| Connection in acc. with standard |
IEC/EN 60079-7 |
| Conductor cross section solid min. |
0.14 mm² |
| Conductor cross section solid max. |
6 mm² |
| Conductor cross section AWG min. |
26 |
| Conductor cross section AWG max. |
10 |
| Conductor cross section flexible min. |
0.14 mm² |
| Conductor cross section flexible max. |
4 mm² |
| Internal cylindrical gage |
A4 |
Standards and Regulations
| Connection in acc. with standard |
CSA |
| |
IEC 60947-7-1 |
| |
IEC/EN 60079-7 |
| Flammability rating according to UL 94 |
V0 |
Environmental Product Compliance
| REACh SVHC |
Lead 7439-92-1 |
| China RoHS |
Environmentally Friendly Use Period = 50 years |
| |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
eCl@ss
| eCl@ss 10.0.1 |
27141120 |
| eCl@ss 11.0 |
27141120 |
| eCl@ss 4.0 |
27141100 |
| eCl@ss 4.1 |
27141100 |
| eCl@ss 5.0 |
27141100 |
| eCl@ss 5.1 |
27141100 |
| eCl@ss 6.0 |
27141100 |
| eCl@ss 7.0 |
27141120 |
| eCl@ss 8.0 |
27141120 |
| eCl@ss 9.0 |
27141120 |
ETIM
| ETIM 2.0 |
EC000897 |
| ETIM 3.0 |
EC000897 |
| ETIM 4.0 |
EC000897 |
| ETIM 5.0 |
EC000897 |
| ETIM 6.0 |
EC000897 |
| ETIM 7.0 |
EC000897 |
UNSPSC
| UNSPSC 6.01 |
30211811 |
| UNSPSC 7.0901 |
39121410 |
| UNSPSC 11 |
39121410 |
| UNSPSC 12.01 |
39121410 |
| UNSPSC 13.2 |
39121410 |
| UNSPSC 18.0 |
39121410 |
| UNSPSC 19.0 |
39121410 |
| UNSPSC 20.0 |
39121410 |
| UNSPSC 21.0 |
39121410 |